BOOM BARRIER

      Magnastop KE-MSB300 Boom Barriers with Magnetic Loop Detection System
 
 

Technical Description
The combination of our proven and reliable electric motor with a lever system represents a simple and extremely reliable drive solution. It permits short opening and closing times without the barrier boom bouncing in the end positions. The lever system locks the barrier boom at both end positions. In the event of a power failure, it can still be moved easily by hand. The complete drive system is attached to the barrier housing as a single unit, and can easily be removed from the housing by removing the mounting screws. A built in spring mechanism provides a precise counterbalance for the barrier boom. The springs are factory set to correspond with the boom length prior to delivery. If necessary, the springs can be easily reset in situ during assembly, for example if the barrier boom is shortened or if signs are attached to the boom. It is also a simple matter to change the handing on-site from right-axial to left-axial.

The Drive Unit
The barrier is driven by a torque motor mounted on a central cast aluminium support. This support also contains the bearings for the drive shaft, the gear box and the mounting for the counterbalance springs The torque motor is designed for alternating current. It requires neither limit switches nor a friction clutch. It is maintenance-free and can be stalled in any position without the risk of damage. In the end positions the motor remains under power assisting the mechanical locking of the barrier boom via the lever system. This reduces the power consumption to a minimum. This power is dissipated in the form of heat, which prevents the occurrence of condensation and corrosion. This guarantees reliable and problem-free operation, especially in cold climatic conditions. The built-in position sensor provides precise barrier boom status information to the associate controller. The self-learning control unit guarantees optimum braking, without the barrier boom bouncing or swinging out of the end position. The barrier is factory wired, tested, ready to connect and supplied with all necessary mounting accessories.

The Housing
The high-quality and robust housing is manufactured from 2 mm zinc phosphate sheet steel then powder coat finished in RAL 2000 (orange) not bleaching and not harmful to the environment. Control units are mounted onto a removable zinc plated sheet steel panel. All of the components within the barrier housing are readily accessible through the maintenance door and removable top cover.

Available Versions
Barriers may be supplied with the barrier boom fitted to either the right or left hand side. In its standard configuration the maintenance access door is positioned on the road side, although on request it can be any one of the other sides.

The Barrier Boom
The barrier boom is extruded from highly stable aluminium alloy to produce an octagonal profile of 100 mm x 55 mm x 1.6 mm and finished with an RAL 9010 white powder coat then applied with bright red reflective tape strips. Hence the boom is readily visible even at night. If the barrier boom is to be any longer than 3.5 metres, it is necessary to fit either a pendulum support or fixed support post. If the available vertical height is restricted the barrier can, at extra cost, be supplied with an articulated boom. In order to calculate the dimensions of the articulated boom, the barrier length (D=) and height (H=) must be supplied.

The Control Unit
The MLC controller was especially developed by Magnetic. Using microprocessor technology to ensure a flexible, modern approach to the control techniques, it possesses all appropriate expansion options including an I/O box and serial communciations interface. The MLC and ancillary control units arefitted on to the fold out mounting plate.

Safety
The following safety instructions and country-specific accident prevention regulations are to be observed for installing and operating.

Magnetic barriers:

1. The concrete foundation must be produced by the customer in accordance with Magnetic Foundation Info MF 5115.
2. The minimum required distance between the end of the barrier boom and the nearest building is 500 mm.
3. The customer must fit all permanent barrier installations with an all-pole main switch which can be locked up.
4. The closing and opening actions must be observed. The mounting of operating elements outside the field of view is not permissible; there must be a line of visibility between the barrier and the control system.

5. It is forbidden for persons or goods to be anywhere within the swing zone of the barrier boom while it is in operation.
6. If the barrier boom is any longer than 3.5 m, a pendulum support or a support post must be mounted.
7. The barrier boom fixture can withstand winds of up to a maximum of force 10 on the Beaufort scale (= 500 N/m2).


The Electrical Connection
Electrical connections are carried out in accordance with factory circuit diagrams. Our control units may necessitate the application of special connection diagrams for certain configurations. This can be supplied by us on request.

Technical Data
KE-MSB300
KE-MSB600
Maximum boom length
mm
3500
6000
Opening and Closing time
s
1.4
4.0
Voltage
V
230/115
230/115
Frequency
Hz
50-60
50-60
Power Consumption
W
120
120
Housing:Width
mm
350
350
Depth
mm
350
350
Height
mm
1010
1010
Weight not including barrier boom
kg
50
50
 
 
 
 
Copyright © 2011 KOMANSU | All rights reserved